Power supply24 V DC
Relay safety output3NO + 1NC (PNP or NPN)
Maximum switching capacity12 A (Distributed on all safety output contacts)
Transistor signal output<500 mA 24 V DC
Contact resistance<100 mΩ
Size117 × 100 × 22.5 mm
Class of pollution4 TYPE
CertificateISO, CE, UL, FCC, TUV
Download
Update TimeDec 26,2024
Detail Information
Safety Relay Product model
Model
QSRN
Certificate
ISO, CE, TYPE 4 
Output
Power supply
24 V DC
Tolerance of voltage
+10% / -20%
Power dissipation
2.9 W
Output
PNP  3NO + 1NC
Transistor signal output
<500 mA 24 V DC
Transistor signal output
<500 mA 24 V DC
Relay contact capacity
AC-1
6 A / 250 V AC / 1500 VA
AC-15
4 A / 240 V AC
DG-1
6 A / 24 V DC / 150 W
DG-13
4 A / 24 V DC
Maximum switching capacity
12 A (Distributed on all safety output contacts)
Contact resistance
<100 mΩ
Minimum load
10 mA / 5 V
Material of contact
AgSnO2 + 0.2µmAu
General parameter
Output fuse (external)
5 A gL/gG
Release response time
<30 ms (From input to output)
Check the resistance at the end of the input component(Touch edge/carpet)
1 kΩ ~ 10 kΩ
Electrical life
80,000 times
Cass of pollution
4 TYPE
Operating temperature
-25℃ ~ 85℃
Operating humidity
35% - 85% (No ice or condensation)
Impulse withstand voltage
2.5 kV
Level of protection
Enclosure IP30, terminal IP20, recommended for installation in cabinet or enclosure IP54
Storage temperature
-40℃ ~ 105℃
Shell material
Flame retardant PA66
Size
117 × 100 × 22.5mm

THE INSTALLATION OF THE CONTROLLER

1. Installation tools

 

(1) Electric drill, drill bit (specification: φ4.3, (φ5.2, φ6.8), tap (specification: M5,M6,M8).Cross and slotted screwdriver, hexagon wrench (specification: 6#.8#), adjustable wrench (specification: 22"), Needle nose pliers.etc

(2) The installation of the controller bracket requires a φ 5.2 drill and M6 tap

(3) The installation ofthe photoelectric support base requires a φ 6.8 drill bit and an M8 tap

(4) The fixing hole of the crimping buckle of the transmission line needs a φ 4.3 drill bit and an M5 tap

 

2. Installation of built-in controller

 Connect the controller directly to the 35mm electrical rail. lnstalled in the electrical cabinet of the machine.

THE INSTALLATION OF THE CONTROLLER
Safety light curtain connected to safety relay 2 circuit safety output wiring diagram
Safety light curtain connected to safety relay 2 circuit safety output wiring diagram
Optical synchronous 3&5 core safety light curtain connection QSRN safety relay wiring diagram
Optical Synchronous 3&5 Core Safety Light Curtain Connection QSRN Safety Relay Wiring Diagram
Controller Dimensional Drawing
Controller Dimensional Drawing
Safety relay -QSRN .STEP
QSRN technical data sheet
Review
  • Loading...

Becoming a DADISICK sales and service partner and resell our products in your country!

These partners are supported by DADISICK with the latest training, tools, knowledge, information and support. please complete this short form.
*Email
Name
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.