Technology-Leading Manufacturer Of Industrial Automation Safety Sensors

Home / All / Safety Products / Ultrasonic Sensor / CSC Series /

CSC18-1000-J55-I-V15 | Ultrasonic Sensor Factory | DADISICK

CSC18-1000-J55-I-V15 | Ultrasonic Sensor Factory | DADISICK
CSC18-1000-J55-I-V15 | Ultrasonic Sensor Factory | DADISICKCSC18-1000-J55-I-V15 | Ultrasonic Sensor Factory | DADISICKCSC18-1000-J55-I-V15 | Ultrasonic Sensor Factory | DADISICK

CSC18-1000-J55-I-V15 | Ultrasonic Sensor Factory | DADISICK

CategoriesCSC Series
BrandDADISICK
ModelCSC Series | CSC18-1000-J55-I-V15
Size:Cylindrical 18 mm
Detection range:60-1000mm
Material:Copper sleeve nickel plated
Connection type:5-pin M12 connector
Output method:Analog current 4-20mA
Security level:IP67
Ambient temperature:-25°C~+70°C (248~343K)
Update TimeNov 21,2024
Detail Information
CSC series analog output/digital output I/U/IU/RS485
Model
CSC18-1000-J55-I-V15
CSC30-2500-J60-I-V15
CSC18-1000-J55-U-V15
CSC30-2500-J60-U-V15
CSC18-1000-J55-R4-V15
CSC30-2500-J60-R4-V15
Detection range
60-1000 mm
150-2500 mm
Blind zone
0-60 mm
0-150 mm
Resolution
0.2 mm
0.2-0.5 mm
Repeatability
±0.15% of full-scale value
Absolute accuracy
±1% (built-in temperature drift compensation)
Response time
120 ms
160 ms
Input type
With synchronization and learning function
Output type: I
1 analog current output 4-20 mA, rise/fall
Output type: U
1 analog voltage output 0-10 V, rise/fall
Output type: R4
1 digital output RS485 modbus-rtu
Weight
45 g
145 g
Electrical data
Power-up Timer
< 500 ms
Operating voltage
10-30 V DC, reverse polarity protection
LED red light
No target is always bright , and no target flashes when studying
LED green Iight
Detected that the target is always bright , and the target flashes when studying
Overpower protection
200 mA , red light and green light flashing at the same time
Load impedance
I / 0-300 Ohm , U / > 1k Ohm
No-load current
≤ 30 mA
Structure
Cylindrical
Material
Copper sleeve nickel plated, flange probe made of PVDF material
Connection type
5-pin M12 connector
Protection Class
IP 67
Environmental parameters
Ambient temperature
-25°C~+70°C (248~343K)
Storage temperature
-40°C~+85°C (233~358K)
Dimensions  (unit: mm)

Dimensions of ultrasonic level measurement CSC series
Electrical connection
Electrical connection diagram of ultrasonic water level CSC series
Data sheet
CSC series data sheet
Operation instructions
CSC series operation instructions
Review
  • Loading...

Becoming a DADISICK sales and service partner and resell our products in your country!

These partners are supported by DADISICK with the latest training, tools, knowledge, information and support. please complete this short form.
*Email
Name
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.