The products here are part of DADISICK's brand product line, which is independently developed, manufactured, and sold.
We provide stable, high-quality products and ensure fast delivery.
Categories | DA-Y & DB-Y Series |
---|---|
Brand | DADISICK |
Model | DA-Y & DB-Y Series | DA-Y30 |
Measuring frequency: | 1Hz-40Hz |
Communication interface: | RS232/RS485 (switchable) |
Laser type: | Class II, 660±15nm, ≤1mW |
Measuring distance | 0.2-30m |
Measurement resolution: | 1mm |
Power supply: | DC15~30V |
Power consumption: | <3.0W |
Protection grade: | IP67 |
Update Time | Dec 25,2024 |
Models comparison
|
||||||
Type A | ||||||
Models | DA-Y10 | DA-Y20 | DA-Y30 | DA-Y50 | DA-Y100 | |
Measuring range | 0.2-10m | 0.2-20m | 0.2-30m | 0.2-50m | 0.2-100m |
|
Output mode | Digital quantity & switch quantity | |||||
Type B | ||||||
Models | DB-Y10 | DB-Y20 | DB-Y30 | DB-Y50 | DB-Y100 | |
Measuring range | 0.2-10m | 0.2-20m | 0.2-30m | 0.2-50m | 0.2-100m | |
Voltage/current output | Can be set to 0~5V / 0~10V / 4~20mA / 0~20mA /0~24mA output *Note 2 | |||||
Voltage output error | 0.2%+0.5mV | |||||
Current output error | 0.2%+0.005mA | |||||
Output mode | Digital quantity, switch quantity, analog quantity |
Specification
|
||||||
Communication interface | RS232/RS485 (switchable) | |||||
Measuring frequency | 1Hz-40Hz |
|||||
Laser type | Class II, 660±15nm, ≤1mW | |||||
Measurement resolution | 1mm | |||||
Measurement error | ±(2mm+d * one ten thousandth) *Note 1 | |||||
Indicator light | Red laser | |||||
Spot size | @1m∅6mm; @10m∅8mm; @20m∅12mm; @30m∅16mm; | |||||
Display | 128x32 dot matrix screen | |||||
Backlight off time | 30 minutes (can be set to normally on) | |||||
Operating mode | Off measurement, continuous measurement | |||||
Transistor switch output | 2 channels (cannot exceed DC36V 0.5A) *Note 3 | |||||
Power supply | DC15~30V | |||||
Power consumption | <3.0W | |||||
Protection grade | IP67 | |||||
Shell material | Die-cast zinc alloy | |||||
Working temperature | -10°C~50°C | |||||
Storage temperature and humidity | -20°C~60°C, 20%~85%RH | |||||
Overheating protection | When the body temperature is higher than 70°C, the measurement will be shut down and when the temperature is lower than 70°C, the measurement will be resumed. | |||||
Dimension | 88.45x40x59.3mm (including connection base) | |||||
Notes | *Note 1: When [Speed Level] is 1. "d" represents the actual distance. In harsh environments, such as when the sun is too strong and the ambient temperature fluctuates too much, there will be a large error in the measurement results. In this case, the effect is better when used with a target reflector. *Note 2: Current and voltage can' t be output at the same time. *Note 3: If the external DC output of the transistor switch exceeds the limited voltage or current, it may cause permanent damage to the instrument. |